Model Name | 700-4G | 1000-4G | 1500-4G | 2000-4G | 2500-4G | 3000-4G | 3600-4G |
Input DC | |||||||
Recommended max. PV power | 0.9kW | 1.2kW | 1.8kW | 2.3kW | 3kW | 3.5kW | 4kW |
Max. input voltage | 600V | ||||||
Rated voltage | 200V | 330V | |||||
Start-up voltage | 60V | 90V | |||||
MPPT voltage range | 50-500V | 80-500V | |||||
Max. input current | 11A | 19A | |||||
Max. short circuit current | 17.2A | 30A | |||||
MPPT number/Max. input strings number | 1/1 | 1/2 | |||||
Output AC | |||||||
Rated output power | 0.7kW | 1kW | 1.5kW | 2kW | 2.5kW | 3kW | 3.6kW |
Max. apparent output power | 0.8kVA | 1.1kVA | 1.7kVA | 2.2kVA | 2.8kVA | 3.3kVA | 3.6kVA |
Max. output power | 0.8kW | 1.1kW | 1.7kW | 2.2kW | 2.8kW | 3.3kW | 3.6kW |
Rated grid voltage | 1/N/PE, 220/230V | ||||||
Rated grid frequency | 50/60Hz | ||||||
Rated grid output current | 3.2A/3.0A | 4.5A/4.3A | 6.8A/6.5A | 9.1A/8.7A | 11.4A/10.9A | 13.6A/13A | 16A |
Max. output current | 4.4A | 5.2A | 8.1A | 10.5A | 13.3A | 15.7A | 16A |
Power Factor | >0.99 (0.8 leading - 0.8 lagging) | ||||||
THDi | <3% | ||||||
Efficiency | |||||||
Max. efficiency | 97.2% | 97.5% | |||||
EU efficiency | 96.5% | 96.8% | |||||
Protection | |||||||
DC reverse-polarity protection | Yes | ||||||
Short circuit protection | Yes | ||||||
Output over current protection | Yes | ||||||
Surge protection | Yes | ||||||
Grid monitoring | Yes | ||||||
Anti-islanding protection | Yes | ||||||
Temperature protection | Yes | ||||||
Integrated DC switch | Optional | ||||||
General Data | |||||||
Dimensions (W*H*D) | 310*373*160 mm | ||||||
Weight | 7.4kg | 7.7kg | |||||
Topology | Transformerless | ||||||
Self consumption | <1W (night) | ||||||
Operating ambient temperature range | -25 ~ +60°C | ||||||
Relative humidity | 0-100% | ||||||
Ingress protection | IP65 | ||||||
Cooling concept | Natural convection | ||||||
Max. operation altitude | 4000m | ||||||
Grid connection standard | VDE-AR-N 4105, VDE V 0124, VDE V 0126-1-1, UTE C15-712-1, NRS 097-1-2, G98, G99, EN 50549-1/-2, RD 1699, UNE 206006, UNE 206007-1, IEC 61727 | ||||||
Safety/EMC standard | IEC 62109-1/-2, IEC 62116, EN 61000-6-1/-2/-3/-4 | ||||||
Features | |||||||
DC connection | MC4 connector | ||||||
AC connection | Quick connection plug | ||||||
Display | LCD | ||||||
Communication | RS485, Optional: Wi-Fi, GPRS |
Models | 2.5K | 3K | 3.6K | 4K | 4.6K | 5K | 6K |
Input DC | |||||||
Recommended max. PV power | 3kW | 3.5kW | 4.2kW | 4.6kW | 5.3kW | 5.8kW | 6.6kW |
Max. input voltage | 550V | 600V | |||||
Rated voltage | 250V | 330V | |||||
Start-up voltage | 60V | 120V | |||||
MPPT voltage range | 50-450V | 90-520V | |||||
Max. input current | 11A/11A | ||||||
Max. short circuit current | 17.2A/17.2A | ||||||
MPPT number/Max. input strings number | 2/2 | ||||||
Output AC | |||||||
Rated output power | 2.5kW | 3kW | 3.6kW | 4kW | 4.6kW | 5kW | 6kW |
Max. apparent output power | 2.8kVA | 3.3kVA | 4kVA | 4.4kVA | 5kVA | 5kVA | 6kVA |
Max. output power | 2.8kW | 3.3kW | 4kW | 4.4kW | 5kW | 5kW | 6kW |
Rated grid voltage | 1/N/PE, 220/230V | ||||||
Rated grid frequency | 50/60Hz | ||||||
Rated grid output current | 11.4A/10.9A | 13.6A/13.0A | 16.0A/15.7A | 18.2A/17.4A | 20.9A/20.0A | 22.7A/21.7A | 27.3A |
Max. output current | 13.3A | 15.7A | 16.0A | 21.0A | 23.8A | 25.0A | 27.3A |
Power Factor | >0.99 (0.8 leading - 0.8 lagging) | ||||||
THDi | <3% | ||||||
Efficiency | |||||||
Max. efficiency | 97.8% | 98.1% | |||||
EU efficiency | 97.1% | 97.3% | |||||
Protection | |||||||
DC reverse-polarity protection | Yes | ||||||
Short circuit protection | Yes | ||||||
Output over current protection | Yes | ||||||
Surge protection | Yes | ||||||
Grid monitoring | Yes | ||||||
Anti-islanding protection | Yes | ||||||
Temperature protection | Yes | ||||||
Integrated DC switch | Optional | ||||||
General Data | |||||||
Dimensions (W*H*D) | 310*543*160 mm | ||||||
Weight | 11.5kg | ||||||
Topology | Transformerless | ||||||
Self consumption | <1W (night) | ||||||
Operating ambient temperature range | -25 ~ +60°C | ||||||
Relative humidity | 0-100% | ||||||
Ingress protection | IP65 | ||||||
Cooling concept | Natural convection | ||||||
Max. operation altitude | 4000m | ||||||
Grid connection standard | VDE-AR-N 4105, VDE V 0124, VDE V 0126-1-1, UTE C15-712-1, NRS 097-1-2, G98, G99, EN 50549-1/-2, RD 1699, UNE 206006, UNE 206007-1, IEC 61727 | ||||||
Safety/EMC standard | IEC 62109-1/-2, IEC 62116, EN 61000-6-2/-3 | ||||||
Features | |||||||
DC connection | MC4 connector | ||||||
AC connection | Quick connection plug | ||||||
Display | LCD | ||||||
Communication | RS485, Optional: Wi-Fi, GPRS | ||||||
Communication | RS485, Optional: Wi-Fi, GPRS |
Models | 7K | 8K | 9K | 10K |
Input DC | ||||
Recommended max. PV power | 10.5 kW | 12 kW | 13.5 kW | 15 kW |
Max. input voltage | 600 V | |||
Rated voltage | 330 V | |||
Start-up voltage | 120 V | |||
MPPT voltage range | 100-500 V | |||
Max. input current | 14 A / 14 A / 14 A | |||
Max. short circuit current | 22 A / 22 A / 22 A | |||
MPPT number/Max. input strings number | 3 / 3 | |||
Output AC | ||||
Rated output power | 7 kW | 8 kW | 9 kW | 10 kW |
Max. apparent output power | 7.7 kVA | 8.8 kVA | 9.9 kVA | 10 kVA |
Max. output power | 7.7 kW | 8.8 kW | 9.9 kW | 10 kW |
Rated grid voltage | 1/N/PE, 220 V / 230 V | |||
Rated grid frequency | 50 Hz / 60 Hz | |||
Rated grid output current | 31.8 A / 30.4 A | 36.4 A / 34.8 A | 40.9 A / 39.1 A | 45.5 A / 43.5 A |
Max. output current | 33.7 A | 36.6 A | 41.3 A | 45.9 A |
Power factor | >0.99 (0.8 leading - 0.8 lagging) | |||
THDi | <3% | |||
Efficiency | ||||
Max. efficiency | 98.0% | |||
EU efficiency | 97.1% | |||
Protection | ||||
DC reverse-polarity protection | Yes | |||
Short circuit protection | Yes | |||
Output over current protection | Yes | |||
Surge protection | Yes | |||
Grid monitoring | Yes | |||
Anti-islanding protection | Yes | |||
Temperature protection | Yes | |||
Integrated AFCI (DC arc-fault circuit protection) | Yes (1) | |||
Integrated DC switch | Optional | |||
General Data | ||||
Dimensions (W*H*D) | 333*579*253 mm | |||
Weight | 18.5 kg | |||
Topology | Transformerless | |||
Self-consumption (night) | <1 W | |||
Operating ambient temperature range | -25 ~ +60°C | |||
Relative humidity | 0-100% | |||
Ingress protection | IP66 | |||
Cooling concept | Natural convection | |||
Max. operation altitude | 4000 m | |||
Grid connection standard | G99, EN 50549-1, IEC 62116, IEC 61727, IEC60068, IEC 61683, EN 50530 | |||
Safety/EMC standard | IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-2/-3/-4 | |||
Features | ||||
DC connection | MC4 connector | |||
AC connection | OT Terminal | |||
Display | LCD | |||
Communication | RS485, Optional: Wi-Fi, GPRS |
Models | 3K | 4K | 5K | 6K | 8K | 10K | 12K | 15K | 20K |
Input DC | |||||||||
Recommended max. PV power | 4.5 kW | 6 kW | 7.5 kW | 9 kW | 12 kW | 15 kW | 18 kW | 22.5 kW | 30 kW |
Max. input voltage | 1100 V | ||||||||
Rated voltage | 600 V | ||||||||
Start-up voltage | 180 V | ||||||||
MPPT voltage range | 160-1000 V | ||||||||
Max. input current | 16 A / 16 A | 32 A / 32 A | |||||||
Max. short circuit current | 20 A / 20 A | 40 A / 40 A | |||||||
MPPT number/Max. input strings number | 2/2 | 2/4 | |||||||
Output AC | |||||||||
Rated output power | 3 kW | 4 kW | 5 kW | 6 kW | 8 kW | 10 kW | 12 kW | 15 kW | 20 kW |
Max. apparent output power | 3.3 kVA | 4.4 kVA | 5.5 kVA | 6.6 kVA | 8.8 kVA | 11 kVA | 13.2 kVA | 16.5 kVA | 22 kVA |
Max. output power | 3.3 kW | 4.4 kW | 5.5 kW | 6.6 kW | 8.8 kW | 11 kW | 13.2 kW | 16.5 kW | 22 kW |
Rated grid voltage | 3/N/PE, 220 V / 380 V, 230 V / 400 V | ||||||||
Rated grid frequency | 50 Hz / 60 Hz | ||||||||
Rated grid output current | 4.6 A / 4.3 A | 6.1 A / 5.8 A | 7.6 A / 7.2 A | 9.1 A / 8.7 A | 12.2 A / 11.5 A | 15.2 A / 14.4 A | 18.2 A / 17.3 A | 22.8 A / 21.7 A | 30.4 A / 28.9 A |
Max. output current | 4.7 A | 6.4 A | 7.9 A | 9.5 A | 12.7 A | 15.9 A | 19.1 A | 23.8 A | 31.8 A |
Power factor | >0.99 (0.8 leading - 0.8 lagging) | ||||||||
THDi | <2% | ||||||||
Efficiency | |||||||||
Max. efficiency | 98.3% | 98.5% | 98.6% | 98.7% | |||||
EU efficiency | 97.7% | 97.9% | 98.0% | 98.1% | |||||
Protection | |||||||||
DC reverse-polarity protection | Yes | ||||||||
Short circuit protection | Yes | ||||||||
Output over current protection | Yes | ||||||||
Surge protection | Yes | ||||||||
Grid monitoring | Yes | ||||||||
Anti-islanding protection | Yes | ||||||||
Temperature protection | Yes | ||||||||
Integrated AFCI (DC arc-fault circuit protection) | Yes (1) | ||||||||
Integrated DC switch | Optional | ||||||||
General Data | |||||||||
Dimensions (W*H*D) | 310*563*219 mm | ||||||||
Weight | 17.8 kg | 18.8 kg | 20 kg | ||||||
Topology | Transformerless | ||||||||
Self-consumption (night) | <1 W | ||||||||
Operating ambient temperature range | -25 ~ +60°C | ||||||||
Relative humidity | 0-100% | ||||||||
Ingress protection | IP66 | ||||||||
Cooling concept | Natural convection | Intelligent redundant fan-cooling | |||||||
Max. operation altitude | 4000 m | ||||||||
Grid connection standard | G99, VDE-AR-N 4105 / VDE V 0124, EN 50549-1, VDE 0126 / UTE C 15 / VFR:2019, RD 1699 / RD 244 / UNE 206006 / UNE 206007-1, CEI 0-21, C10/11, NRS 097-2-1, EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530 | ||||||||
Safety/EMC standard | IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-2/-3/-4 | ||||||||
Features | |||||||||
DC connection | MC4 connector | ||||||||
AC connection | Quick connection plug | ||||||||
Display | LCD | ||||||||
Communication | RS485, Optional: Wi-Fi, GPRS |
On Grid Residential Inverter
0.7-10KW
1-3 MPPTs
Single Phase 220-240V 50/60Hz
Single Phase 220-240V 50/60Hz
On Grid Residential Inverter
3-20KW
2 MPPTs
Three Phase 380-415V 50/60Hz
Three Phase 380-415V 50/60Hz
On Grid Commercial Inverter
25-70KW
5/6 MPPTs
Three Phase 380-415V 50/60Hz
Three Phase 380-415V 50/60Hz
On Grid Commercial Inverter
50-125KW
10 MPPTs
Three Phase 380-415V 50/60Hz
Three Phase 380-415V 50/60Hz
On Grid Utility Scale Inverter
215-255KW
9-14 MPPTs
Three Phase 800V 50/60Hz
Three Phase 800V 50/60Hz
Energy Storage Inverter
3-6KW
Battery Voltage: 42-58V
Single Phase 220-240V 50/60Hz
Single Phase 220-240V 50/60Hz
Energy Storage Inverter
5-10KW
Battery Voltage: 120-600V
Three Phase 380-415V 50/60Hz
Three Phase 380-415V 50/60Hz